#======================================================================= # target.sl - Calculations at the target electrode of the Buncher lens. # # This program computes a measure of the dispersion of ions hitting # the target electrode. Since the ions have been focused by the # Buncher lens, we expect the dispersion to be small. # # Upon compilation, this SL program can be used as an near exact # replacement for the TARGET.PRG program in the _Buncher example of # SIMION 7.0. # # HISTORY: # 2003-11 - ported to SL (D.J.Manura, Scientific Instrument Services, Inc.) # Based on the TARGET.PRG example in SIMION 7.0. # $Revision: 1.2 $ $Date: 2004/07/17 20:54:45 $ #======================================================================= #===== variables adjustable first_ion = 0 # flag for first ion adjustable max_time = 0 # holds max tof adjustable min_time = 0 # holds min tof #===== subroutines # Calculate and display results and the end of simulation. sub terminate # no printing for first ion if first_ion == 0 first_ion = 1 # flag first ion max_time = ion_time_of_flight min_time = ion_time_of_flight else # compute if not first ion max_time = max(ion_time_of_flight, max_time) min_time = min(ion_time_of_flight, min_time) print("Avg TOF = # Delta TOF = # usec", (max_time + min_time)/2, max_time - min_time) endif endsub |
|